<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-09 02-49-44
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 45 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
14 kHz 73 kHz 11484 14,4375
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,5 dBr 5,68 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 73 kHz MIN: 14 kHz % above 76 kHz: 14,4375 Acquired: 2025/12/09 2.48.40 Total samples: 11484 Equivalent time: 0:09:34 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,4 dBr MIN: 4,5 dBr AVE: 5,68 dBr % above 12,2 dBr: 0,0 Last value: 5,2 dBr (2025/12/09 2.48.39) 02.34 02.36 02.38 02.40 02.42 02.44 02.46 02.48 0 2 4 6 Pm [dBr]